PICKED UP HERE
    Art Lighting Production, s.r.o.
    Komenského 427
    Újezd u Brna
    664 53

    Mon - Fri 8 - 11 a.m., 12 - 15 p.m.


    PAYMENT METHODS
    We normally accept cash payments
    bank transfer and cash on delivery.
    It is not possible to pay by card!


    SHIPPING
    We normally ship with DPD,
    in the case of pallet consignments
    according to contract

    TSX 48 wallsystem - 48x 1,2kW   (1023119)


    TSX 48 wallsystem - 48x 1,2kW  (1023119)
    • TSX 48 wallsystem - 48x 1,2kW  (1023119)
    The dimming equipment TSX 48 enables connecting of forty eight circuits with
    the load of 1.2 kW per circuit. The fully digital control unit LE 24×2 enables many
    definable functions, it is fitted with two DMX inputs and an Ethernet port for
    communication with computer. The equipment enables storing of own memories
    and their start from the control unit or from external push-button station. The unit
    is intended for fixed installation in theatres, community centers, TV studios etc.
    ID:
    1023119
    PRICE
    4 720 EUR
     net of VAT / pcs
    Dimmer features
    • Wall mounting
    • Passive and active cooling
    (controlled depending on temperature)
    • Full digital control with Le 24×2 control unit
    • 2× digital input DMX 512
    (connection to connecting block).
    • Ethernet port RJ-45
    • 2 analog outputs
    • 16 analog inputs
    • Possibility of storing of own memories
    • Start of the preset scenes by push-button
    stations. These push-button stations have
    got 6 presets and can be placed in any
    location in the building.
    • Protection of individual circuits with circuit
    breakers C6A

    Le24 control unit features
    • Voltage indication of all phases on the display
    • Setting the start address for DMX port A and B
    • Assignment of any DMX address to any dimmer
    (PATCH)
    • 8 curves of output characteristics
    • Setting dimmer preheating (PREHEAT) 0–10 %
    • Maximal voltage setting of the Dimmer 90–100 %
    • Setting response time of 30 ms, 100 ms, 300 ms
    • Assignment of analog inputs to individual dimmers
    • Behaviour setting by signal drop–out–hold last,
    black out, fixed value, stored preset
    • Diagnostics using Ethernet interface
    • Monitoring and setting through PC
    • Locking of set values

    Technical Specification

    Supply Voltage 3ˇż 230 V/400 V, 50 Hz, TN-S
    Dimensions (WˇżHˇżD) [mm] 830ˇż1060ˇż105
    Weight 70 kg
    Number of circuits 48
    Max. total load 57,6 kW
    Max. feed current 3ˇż 80 A
    Max. load per circuit 1,2 kW
    Min. load per circuit 25 W
    Control signal DMX 512
    Enclosure IP20
    Operating temperature 10.50˘Ş C
    • Testing mode